NOTOS 3NS Three Screw Pump

NOTOS® 3NS Three Screw Pump

Lightweight and Universally Applicable due to Small Footprint

Suitable for use in a wide range of industrial sectors and applications, the self-priming NOTOS® 3NS three screw pumps are true lightweights and have a small footprint.

Due to the optimisation by means of the High Efficiency Unique Design (HEUD) concept, three screw pumps convince with a high efficiency. In addition, continuous delivery with low pulsation and a flow of the medium with minimal turbulence is ensured. This results in gentle product handling. It is assured by means of state-of-the-art technology, precise tolerances and an optimised screw profile. In addition to a drive screw that transmits torque via a thin hydrodynamic film, 3NS three screw pumps have two rotating, intermeshing driven screws. This makes them particularly suitable for non-abrasive and non-corrosive media as well as for liquids with low to medium viscosity, such as lubricants. Through an optional upgrade, NOTOS® multi screw pumps meet the American Petroleum Institute (API) standards relevant to the oil & gas and petrochemical industries. Furthermore, thanks to the wide range of materials, they are versatile and can be used in a wide variety of applications. In addition to grey cast iron and chrome-nickel steel, they are also available in duplex, superduplex or hastelloy steel. This ensures low maintenance and thus low life cycle costs.

Get a personalized offer now!

NOTOS 3NS Three Screw Pump

1 Screws
Nitrated in alloy steel or in stainless steel. The HEUD (High Efficiency Unique Desgin) provides excellent performance.

2 Housing with optional heating jacket
Thanks to the optional heating jacket, the conveyed medium can be kept at a certain level. In addition, the liner is replaceable and available with various connection configurations, for example top top, side top or in line.

3 Bearing Bushes
Internal bearing bushes helps to support radial loads.

4 Mechanical Seal
Under suction pressure just one mechanical seal is required for the 3NS. Magnetic drive optional.

Size*

Pressure max.

(bar)

Capacity max. 

(m3/h)

Operating rotational speed

(rpm)

3NS-/25M2 25 4 3.600
3NS-/25M3 25 7 3.600
3NS-/25M4 25 13 3.600
3NS-/25-4 25 15 3.600
3NS-/25-5 25 20 3.600
3NS-/25-6 25 30 3.600
3NS-/25-7 25 40 3.600
3NS-/25-8 25 50 3.600
3NS-/25-9 25 60 3.600
3NS-/25-10 25 80 3.600
3NS-/25-11 25 100 3.600
3NS-/25-12 25 140 3.600
3NS-/25-13 25 200 3.600
3NS-/25-14 25 270 3.600
3NS-/25-15 25 400 3.600
3NS-/80-4 80 15 3.600
3NS-/80-5 80 20 3.600
3NS-/80-6 80 30 3.600
3NS-/80-7 80 40 3.600
3NS-/80-8 80 50 3.600
3NS-/80-9 80 60 3.600
3NS-/80-10 80 80 3.600
3NS-/80-11 80 100 3.600
3NS-/80-12 80 140 3.600
3NS-/80-13 80 200 3.600
3NS-/120-7 120 40 3.600
3NS-/120-8 120 50 3.600
3NS-/120-9 120 60 3.600

*Further sizes and technical data on request.

  • High efficiency
  • Easy maintenance
  • Lightweight and small footprint
  • Extremely low noise and vibration
  • Low life cycle costs
  • Wide range of applications
  • Wide range of materials
  • Optionally according to API 676 (American Petroleum Institute) requirements

You may also be interested in:

NOTOS® 2NS Screw Pump

Drive screw transmits the torque via a hydrodynamic film to the second screw.

NOTOS® 4NS Geared Twin Screw Pump

The torque is transferred to the driven shaft via helical gears.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.